Lovato Orange BF 4 Pole Contactor, 2NO/2NC, 115 A, 37 kW, 230 V ac Coil

  • RS Stock No. 146-9049
  • Mfr. Part No. BF80T2A230
  • Manufacturer Lovato
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): IT
Product Details

Highly conductive auxiliary contacts with four contact points
Quick connect - snap on accessory mounting
Distinct contact status indication
Up to four auxiliary contacts can be mounted
Mechanical interlock only 5mm deep
Positive (force) guided contacts
(mechanically-linked per IEC)
three-pole contactors, 9 to 110A IEC AC3 duty / 5 to 75HP 480V - 7.5 to 100HP 600V UL/CSA
Four-pole contactors, 25 to 125A in AC1 duty
Power factor correction contactors, 7.5 to 75kvar at 400V IEC / 9 to 80kvar at 480V UL/CSA
Types with 2NO+2NC or 4NC main power poles
Types for photovoltaic applications
Highly conductive auxiliary contacts
Coils with AC or DC supply
Wide-range coils with electronic control for contactors from 40 to 80A AC3
Low-consumption versions for control relays and 9-
38A contactors in IEC AC3 duty

Specifications
Attribute Value
Coil Voltage 230 V ac
Number of Poles 4
Contact Current Rating 115 A
Power Rating 37 kW
Range Orange
Series BF
Normal State Configuration 2NO/2NC
Contact Voltage Rating 230 V ac
Terminal Type Clamp Terminal
Width 114.6mm
Minimum Operating Temperature -50°C
Maximum Operating Temperature +70°C
Length 73mm
Depth 136mm
1 In Global stock for delivery within 4 - 6 working days
Price Each
MYR 2,607.02
units
Per unit
1 +
MYR2,607.02
Related Products
Spring-lock type keeps a high connection also under ...
Description:
Spring-lock type keeps a high connection also under the situation by which the vibration is received. Unlike screw type, stable contact power keeps for long time by spring pressure, there is no need to maintenance like re-screwing. When the terminal ...
A terminal block mounted on the PCX series ...
Description:
A terminal block mounted on the PCX series is 3.5mm pitch. It is possible to check by insert φ2 test pin to checking hole. Open-closing button of connecting spring is possible to use + and – driver. This series don’t ...
Each terminal pitch is 3.5mm with new spring-lock ...
Description:
Each terminal pitch is 3.5mm with new spring-lock terminals. It is possible to check by insert Ф2 test pin to checking hole. Open-closing button of connecting spring is possible to use + and – driver. You don't need stopper by ...
Hum-free MCS installation contactor. Low-noise continuous operation due ...
Description:
Hum-free MCS installation contactor. Low-noise continuous operation due to a special magnet system with low-loss winding and iron core. The contacts can be used as both main and auxiliary contacts. All devices are furnished as standard with a switch position ...