Siemens Overload Relay - NO/NC, 7 → 10 A F.L.C, 10 A Contact Rating, 4 kW, 3P

  • RS Stock No. 706-1588
  • Mfr. Part No. 3RU2116-1JB0
  • Manufacturer Siemens
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

Overload Relay - 3RU range

Switch position indicator and test function
STOP button
Selector switch for manual/automatic reset
Screw connection or Spring-clamp versions
Impulse voltage resistance 6 kV
Insulation voltage 690V
Surface or DIN-rail stand-alone mounts available, see 706-1699 etc

The 3RU21 thermal overload relays up to 80 A have been designed for current-sensitive protection of loads with normal starting.
These thermal overload relays for use with Sirius Size S0 & S00 Contactors

Note

Screw terminals can only be used with screw terminal overloads and spring terminals can only be used with spring terminal overloads.

Approvals

CE, UL, CSA

Siemens Sirius Range Contactor & Control Relays

Specifications
Attribute Value
FLC Motor Rating 7 → 10 A
Contact Current Rating 10 A
Pole Configuration 3P
Range Sirius Innovation
Contact Voltage Rating 690 V ac
Mounting Style Direct Contactor
Series 3RU
Normal State Configuration NO/NC
Number Of Auxiliary Contacts 2
Power Rating 4 kW
Reset Method Automatic, Manual
Terminal Type Screw
Depth 73mm
Length 87mm
Width 45mm
Minimum Operating Temperature -40°C
Operating Temperature Range -40 → +70 °C
Maximum Operating Temperature +70°C
13 In Global stock for delivery within 4 - 6 working days
Price Each
Was MYR199.92
MYR 197.84
units
Per unit
1 +
MYR197.84
Related Products
Tripping class 10 Phase failure sensitivityHand, Automatic or ...
Description:
Tripping class 10 Phase failure sensitivityHand, Automatic or manual reset selectable.
The 3RU21 thermal overload relays up to 80 ...
Description:
The 3RU21 thermal overload relays up to 80 A have been designed for current-sensitive protection of loads with normal starting.These thermal overload relays for use with Sirius Size S0 & S00 Contactors. Switch position indicator and test functionSTOP buttonSelector switch ...
Trip Class 10Coil and auxiliary contact repeat terminalsTrip ...
Description:
Trip Class 10Coil and auxiliary contact repeat terminalsTrip fault indicationManual/auto resetSingle phase differential protectionTemperature compensated trip: -20°C to +60°C.
One N/O and one N/C auxiliary contactTrip class ...
Description:
One N/O and one N/C auxiliary contactTrip class 10AManual/auto reset80 x 44 x 94mm (H x W x D) (4 to 11kW) Vertical mountingFor use with A series contactors4 to 11 kW for contactor series A9 to A30.