Pneumatic Timers

Pneumatic timers are used in industrial systems where time needs to be measured. They are used in place of electrical timers, where the use of electricity is unsafe or undesirable, for example where flammable materials are present. 


Most pneumatic timers use a chamber and a piston to measure time. Air is allowed into the chamber, which pushes the piston towards the end and allows a precise time to be set. 


Pneumatic timers do not use electrical current and are very accurate. 


What are pneumatic timers used for?

Pneumatic timers are used where an electrical current is undesirable, restricted, unavailable or dangerous, such as in the mining, oil and gas industries. You can use them where precise time control is important. By utilising a piston and control valve rather than an electrical current found in a standard timer, pneumatic timers do not generate sparks that could cause fires or explosions. 


Types of pneumatic timers 

Choose the timer most suitable for your needs depending on maximum and minimum operating pressures, temperatures and time required. Certain models have Hazardous Area Certification.






...
Read more Read less

Filters

Viewing 1 - 13 of 13 products
Results per page
Description Price Manufacturer Series Minimum Operating Pressure Maximum Operating Pressure Minimum Operating Temperature Maximum Operating Temperature Minimum Time Maximum Time
RS Stock No. 305-5996
Mfr. Part No.81503720
BrandCrouzet
MYR815.09
Each
units
81 2bar 8 bar -5°C +50°C 0.1s 30s
RS Stock No. 410-523
Mfr. Part No.PRT-B10
BrandParker
MYR867.28
Each
units
PRT 3bar 8 bar -15°C +60°C 10s 180s
RS Stock No. 410-517
Mfr. Part No.PRT-A10
BrandParker
MYR850.21
Each
units
PRT 3bar 8 bar -15°C +60°C 0.1s 30s
RS Stock No. 410-488
Mfr. Part No.PRT-C10
BrandParker
MYR763.21
Each
units
PRT 3bar 8 bar -15°C +60°C 0.1s 30s
RS Stock No. 724-891
Mfr. Part No.81503710
BrandCrouzet
MYR834.70
Each
units
81 2bar 8 bar -5°C +50°C 0.1s 15s
RS Stock No. 410-498
Mfr. Part No.PRT-E10
BrandParker
MYR875.23
Each
units
PRT 3bar 8 bar -15°C +60°C 0.1s 3s
RS Stock No. 777-126
Mfr. Part No.04043102000
BrandNorgren
MYR601.24
Each
units
04 2bar 10 bar -20°C +80°C 0.2ms 0.4ms
RS Stock No. 384-333
Mfr. Part No.VR2110-01
BrandSMC
MYR733.05
Each
units
VR 0.1MPa 1 MPa -5°C +60°C 0.5s 60s
RS Stock No. 725-024
Mfr. Part No.81507720
BrandCrouzet
MYR888.13
Each
units
81 2bar 8 bar -5°C +50°C 0.1s 30s
RS Stock No. 777-053
Mfr. Part No.M/1430
BrandNorgren
MYR3,722.69
Each
units
- 2bar 10 bar +5°C +80°C 0.2s 5s
RS Stock No. 466-5746
Mfr. Part No.81503725
BrandCrouzet
MYR1,068.75
Each
units
81 2bar 8 bar -5°C +50°C 0.1s 60s
RS Stock No. 305-6006
Mfr. Part No.81506710
BrandCrouzet
MYR673.06
Each
units
81 2bar 8 bar -5°C +50°C 0.1s 15s
RS Stock No. 410-460
Mfr. Part No.PRT-F10
BrandParker
MYR882.02
Each
units
PRT 3bar 8 bar -15°C +60°C 0.1s 3s
Related Products
Professionally assembled contactor Timers by Schneider Electric provide ...
Description:
Professionally assembled contactor Timers by Schneider Electric provide you with the option of delaying timed functions on your control circuit linked via the main contactor. This can be beneficial in controlling pre-set on/off operations cyclically or at a defined interval, ...
The Hengstler 497 series 5-digit preset pneumatic counter ...
Description:
The Hengstler 497 series 5-digit preset pneumatic counter can be used for controlling pneumatic circuits and installations. When the preset value is reached, the input pressure appears at the output. This counter, being completely pneumatic in operation, is particularly suited ...
Logic units are best thought of as miniature ...
Description:
Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they ...
The Parker PLJ series YES pneumatic logic module ...
Description: