Filter Fans

Filter fans are used to purify the air of contaminants and recirculate it in order to avoid heat build-up within a device. The filter attaches behind the blades of the fan to pick up dust and other airborne particles as the air passes through. 


How to use a fan filter

To control the temperature of an environment using a filter fan, you should make sure that the fan is drawing cool air into the device and directing the warm air outwards. Not only will this ensure that air is circulating freely, it will will also prevent excess dust build-up. Filter fans are used in combination with an appropriate filter exhaust depending on the type and level of filtration needed. 


What are fan filters used for?

Filter fans can be used in both indoor and outdoor applications to prevent unwanted heat and dust build-up inside an electrical device or enclosure. They are also very often seen in laboratory or medical facilities to remove potentially harmful contaminants and to maintain a clean-room environment. 


...
Read more Read less

Filters

Viewing 81 - 100 of 139 products
Results per page
Description Price Unimpeded Air Flow Noise Level Filtered Air Flow Input Current Input Power Rating AC or DC Operation Face Dimensions Installation Depth Supply Voltage Face Height Face Width Bearing Type Configuration IP Rating
RS Stock No. 184-9914
Mfr. Part No.7F.50.8.230.5630
BrandFinder
MYR2,006.85
Each
units
- 72dB(A) 630m³/h 550mA 130W AC 320 x 320mm 145mm 230 V ac 320mm 320mm Ball - IP54
RS Stock No. 251-071
Mfr. Part No.PF65000 11665102055
MYR846.51
Each
units
831m³/h 54dB 480m³/h 360mA 80W AC 320 x 320mm 150mm 230 V ac - - - - IP54
RS Stock No. 756-9806
Mfr. Part No.3241.110
BrandRittal
MYR828.12
Each
units
250m³/h 56dB 205m³/h 520mA 46W AC 255 x 255mm 107mm 115 V ac 255mm 255mm - - IP54
RS Stock No. 177-9014
Mfr. Part No.NSYCVF560M230PF
MYR846.70
Each
units
- 59dB 562 m³/h @ 50 Hz, 586 m³/h @ 60 Hz 0.37 A @ 60 Hz, 0.52 A @ 50 Hz 68 W @ 50 Hz, 85 W @ 60 Hz AC 316 x 336mm 161mm 207 → 244 V 336mm 316mm Ball - IP54
RS Stock No. 251-043
Mfr. Part No.PF65000 11665152055
MYR674.51
Each
units
831m³/h 54dB 480m³/h 800mA 90W AC 320 x 320mm 150mm 115 V ac - - - - IP54
RS Stock No. 250-781
Mfr. Part No.PF65000 11665103055
MYR890.65
Each
units
831m³/h 54dB 505m³/h 360mA 80W AC 320 x 320mm 150mm 230 V ac - - - - IP55
RS Stock No. 182-9834
Mfr. Part No.01881.2-00
BrandSTEGO
MYR468.03
Each
units
118m³/h 56dB 63m³/h 171mA 4.1W DC 124 x 124mm 79mm 24 V dc 124mm 124mm Ball Square IP54
RS Stock No. 184-9899
Mfr. Part No.7F.20.9.024.1020
BrandFinder
MYR381.92
Each
units
- 37.5dB(A) 24m³/h 150mA 3.6W DC 120 x 120mm 41.4mm 24 V dc 120mm 120mm Ball - IP54
RS Stock No. 915-9984
Mfr. Part No.01872.0-30
BrandSTEGO
MYR465.73
Each
units
170m³/h 55dB(A) 139m³/h 310mA 45W AC 215 x 215mm 117mm 230 V ac 215mm 215mm Ball Rectangular IP54
RS Stock No. 756-9789
Mfr. Part No.3239.124
BrandRittal
MYR1,104.16
Each
units
105m³/h 46dB 100m³/h 280mA 6W DC 204 x 204mm 90mm 24 V dc 204mm 204mm - - IP54
RS Stock No. 733-6191
Mfr. Part No.01861.0-02
BrandSTEGO
MYR1,227.71
Each
units
- 67dB 575m³/h - 85W AC 354 x 354mm 107mm 120 V ac 354mm 354mm - - IP32
RS Stock No. 468-2779
Mfr. Part No.01821.0-02
BrandSTEGO
MYR381.40
Each
units
- 40dB 23m³/h 180mA 15W AC 224 x 165mm 62mm 120 V ac 224mm 165mm - - IP55
RS Stock No. 916-0038
Mfr. Part No.01880.0-00
BrandSTEGO
MYR346.48
Each
units
24m³/h 38dB(A) 15m³/h 70mA 12W AC 120 x 120mm 72mm 230 V ac 120mm 120mm Ball Rectangular IP54
RS Stock No. 184-9908
Mfr. Part No.7F.50.8.230.4230
BrandFinder
MYR887.24
Each
units
- 53dB(A) 230m³/h 170mA 40W AC 250 x 250mm 113mm 230 V ac 250mm 250mm Ball - IP54
RS Stock No. 184-9897
Mfr. Part No.7F.20.8.120.1020
BrandFinder
MYR361.43
Each
units
- 27dB(A) 24m³/h 230mA 17W AC 120 x 120mm 54.4mm 120 V ac 120mm 120mm Ball - IP54
RS Stock No. 756-9795
Mfr. Part No.3240.110
BrandRittal
MYR882.44
Each
units
160m³/h 46dB 121m³/h 360mA 33W AC 255 x 255mm 107mm 115 V ac 255mm 255mm - - IP54
RS Stock No. 177-9017
Mfr. Part No.NSYCVF850M230PF
MYR1,003.98
Each
units
- 75 → 76dB 803 m³/h @ 60 Hz, 838 m³/h @ 50 Hz 0.65 A @ 50 Hz, 0.85 A @ 60 Hz 150 W @ 50 Hz, 195 W @ 60 Hz AC 316 x 336mm 162mm 207 → 244 V 336 316mm Ball - IP54
RS Stock No. 756-9815
Mfr. Part No.3241.124
BrandRittal
MYR1,736.94
Each
units
230m³/h 54dB 205m³/h 200mA 25W DC 255 x 255mm 107mm 24 V dc 255mm 255mm - - IP54
RS Stock No. 251-087
Mfr. Part No.PF42500 11642101055
MYR397.80
Each
units
205.7m³/h 40dB 156m³/h 120mA 18W AC 252 x 252mm 97mm 230 V ac - - - - IP54
RS Stock No. 756-9783
Mfr. Part No.3239.600
BrandRittal
MYR1,708.39
Each
units
105 → 120m³/h 46 dB, 49 dB 100 m³/h, 108 m³/h, 87 m³/h, 93 m³/h 120mA 17 W, 19 W AC 204 x 204mm 90mm 230 V ac 204mm 204mm - - IP54
Related Products
Designed for applications with limited space Airflow is ...
Description:
Designed for applications with limited space Airflow is at right angles to the intakeHigh static pressure capabilitiesConnections are wire endedLocked rotor protectionBall bearing typeHigh temperature low power operation.
Aerodynamic bearingsHigh static pressuresLong life due to aerodynamic ...
Description:
Aerodynamic bearingsHigh static pressuresLong life due to aerodynamic bearings without heat dependenceQuick Fastener P14 (Air Inlet / Air Outlet)Compact / Light weightLow vibration.
Designed for applications with limited space Airflow is ...
Description:
Designed for applications with limited space Airflow is at right angles to the intakeHigh static pressure capabilitiesConnections are wire endedLocked rotor protectionBall bearing typeHigh temperature low power operation.
Comair Rotron auto restart radial blowers feature electronically ...
Description: