Current Transducers

Current transducers, or current sensors, are an electrical component that detects electric current in a wire and converts it into another type of electrical signal proportional to the current value. The generated signal could be analogue voltage, current or a digital output. This generated signal can be then used to display the measured current in an ammeter, or can be used for the purpose of controlling other circuits.

Current Transducer Types

Current sensors can be either open-loop or closed-loop.
•Open-Loop Sensor: This type measures AC and DC currents and provides electrical isolation between the circuit being measured and the output of the sensor. Open-loop current sensors are generally preferred in battery-powered circuits.


•Closed-Loop Sensor: The Closed-Loop sensor is sometimes called a ’Zero-Flux’ sensor because it features a Hall-Effect sensor that feeds back an opposing current into a secondary coil, wound on the magnetic core to zero the flux produced in the magnetic core by the primary current. Closed-loop sensors are often used when high accuracy is essential.

...
Read more Read less

Filters

Viewing 1 - 20 of 358 products
Results per page
Description Price Input Current Range Sensor Technology Nominal Current Output Current Range Supply Voltage Transformer Type Maximum Cable Diameter Sensor Type Mounting Type Frequency Bandwidth Accuracy Bore Size Minimum Operating Temperature Series
RS Stock No. 286-361
Mfr. Part No.LV 25-P
BrandLEM
MYR316.59
Each
units
- Closed Loop 0 → 14 25mA 12 → 15 V - - Hall Effect PCB Mount - ±0.9 % - 0°C LV
RS Stock No. 914-5310
Mfr. Part No.CT132TRAN10A-5/10V
BrandHOBUT
MYR144.39
Each
units
- - 10A - 15 → 30 V - - Loop Sensor DIN Rail 45 → 65 Hz Class 0.5 % 21mm -15°C CT132TRAN
RS Stock No. 914-5288
Mfr. Part No.CT132TRAN100A-4/20MA
BrandHOBUT
MYR177.17
Each
units
- - 100A 4 → 20mA 15 → 30 V - - Loop Sensor DIN Rail 45 → 65 Hz Class 0.5 % 21mm -15°C CT132TRAN
RS Stock No. 497-221
Mfr. Part No.LA 25-P
BrandLEM
MYR302.21
Each
units
- Closed Loop 0 → 55A 25mArms 12 → 15 V - - Hall Effect PCB Mount DC to 200 kHz ±1.25 % - -25°C LA
RS Stock No. 914-5313
Mfr. Part No.CT132TRAN20A-5/10V
BrandHOBUT
MYR163.33
Each
units
- - 20A - 15 → 30 V - - Loop Sensor DIN Rail 45 → 65 Hz Class 0.5 % 21mm -15°C CT132TRAN
RS Stock No. 181-2129
Mfr. Part No.CSLA2CD
BrandHoneywell
MYR95.06
Each
units
- Open Loop 0 → 72A - 6 → 12 V dc - - Hall Effect PCB Mount - - 10.9mm -25°C CSL
RS Stock No. 321-6286
Mfr. Part No.LAH25-NP
BrandLEM
MYR104.65
Each
units
- Closed Loop 25A 25mArms 12 → 15 V - - Hall Effect PCB Mount DC to 200 kHz ±0.3 % - -25°C LAH
RS Stock No. 169-7656
Mfr. Part No.CSLA2DK
BrandHoneywell
MYR148.869
Each (In a Box of 50)
units
- - - Maximum of 400A 6 → 12 V dc - - Hall Effect PCB Mount - - - -25°C CSL
RS Stock No. 499-5536
Mfr. Part No.AP 50 B10
BrandLEM
MYR511.34
Each
units
- Closed Loop 50A - 24 V dc - - - DIN Rail 30 → 2000 Hz ±1 % 18mm -20°C AP
RS Stock No. 121-8179
Mfr. Part No.CSLA2DK
BrandHoneywell
MYR181.39
Each
units
- - 20 Maximum of 400A 6 → 12 V dc - - Hall Effect PCB Mount - - - -25°C CSL
RS Stock No. 321-6315
Mfr. Part No.LTS 15NP
BrandLEM
MYR75.42
Each
units
- Closed Loop 0 → ±48A - 5 V - - Hall Effect PCB Mount DC 100 to 200 kHz ±0.2 % 3.2mm -40°C LTS
RS Stock No. 301-9495
Mfr. Part No.HAS 100S
BrandLEM
MYR117.31
Each
units
- Open Loop ±300A - 15 V - - Hall Effect Panel Mount DC to 50 kHz ±1 % 20.4 x 10.4mm -10°C HAS
RS Stock No. 527-8466
Mfr. Part No.DHR 100 C420
BrandLEM
MYR874.65
Each
units
- Open Loop 100A 4 → 20mA 20 → 50 V dc - - Hall Effect Panel Mount DC 20 to 6000 Hz ±1 % 32mm -40°C DHR
RS Stock No. 301-9502
Mfr. Part No.HAS 200S
BrandLEM
MYR112.16
Each
units
- Open Loop ±600A - 15 V - - Hall Effect Panel Mount DC to 50 kHz ±1 % 20.4 x 10.4mm -10°C HAS
RS Stock No. 793-4632
Mfr. Part No.ATO-75BILD10
BrandLEM
MYR126.49
Each
units
- - 90A 90mA - - - - - 50 Hz, 60 Hz ±1 % 10mm -25°C CAS
RS Stock No. 180-7357
Mfr. Part No.LA 55-P
BrandLEM
MYR115.74
Each
units
- Closed Loop 0 → 70A 50mArms 12 → 15 V - - Hall Effect PCB Mount DC to 200 kHz ±0.9 % - -40°C LA
RS Stock No. 198-841
Mfr. Part No.AT 5 B5
BrandLEM
MYR225.92
Each
units
- - 5A - - - - - Cable Tie 50/60 Hz ±1.5 % 16mm -20°C AT
RS Stock No. 446-0636
Mfr. Part No.DK 300 B420
BrandLEM
MYR2,333.67
Each
units
- - 300A 4 → 20mA 20 → 50 V dc, 22 → 38 V ac - - - Panel Mount - ±1 % 21.7mm -20°C DK
RS Stock No. 666-8182
Mfr. Part No.CASR 6-NP
BrandLEM
MYR73.66
Each
units
- Closed Loop 6A - 5.25 V - - - PCB Mount 200 → 300 kHz ±0.8 % - -40°C CASR
RS Stock No. 499-5592
Mfr. Part No.APR 50 B10
BrandLEM
MYR567.85
Each
units
- Closed Loop 50A - 24 V dc - - - DIN Rail 30 → 6000 Hz ±1 % 18mm -20°C APR
Related Products
The optional holding device ensures the Rogowski coil ...
Description:
The optional holding device ensures the Rogowski coil is securely seated on busbars that are 5 ... 10 mm thick. During installation, the coil housing is pushed onto the flange of the holding device and snaps in automatically.
Single-pole closed-loop current transducers based on the Hall ...
Description:
Single-pole closed-loop current transducers based on the Hall effect principleVoltage output3 different input ranges via selection pinsCompact format for mounting on p.c.b.Excellent precision and good linearityLow temperature driftBody material plastic to UL94-V0.
Compact PCB mounting designEta technologyExternal reference input (Stock ...
Description:
Compact PCB mounting designEta technologyExternal reference input (Stock No. 435-8779)Very low temperature driftWide frequency responseHigh noise immunityCurrent overload capacityBody material plastic to UL94-V0.
Current transducers LF-S Series for the electronic measurement ...
Description: