Analogue Panel Voltmeters

Analogue panel voltmeters are instruments that measure the voltage, or potential deviation, between two points in an electrical circuit. A pointer moves along a scale proportional to the voltage level of the circuit. The difference in movement indicates the potential of the electrical charge between circuit points A and B. Digital panel voltmeters do the same job, but have digital readouts.

What are analogue panel voltmeters used for?

Analogue panel voltmeters can measure voltage levels in generators or fixed machinery. They're commonly used in chemical processing plants where pressure, temperature or fluid-flow readings can be converted into voltage measurements.

Types of analogue panel voltmeters

  • Moving coil voltmeters have either permanent magnets or dynamometers as measuring components with low power consumption benefits.
  • Moving iron voltmeters can measure both AC and DC currents by producing a deflective torque. The torque-to-weight ratio is high which means increased accuracy of readings.
  • Electrostatic voltmeters measure current flow based on attracting, repulsion or symmetry between two electrically charged plates. Their benefits is the high voltage range capacity of 200KV.

...
Read more Read less

Filters

Viewing 41 - 60 of 153 products
Results per page
Description Price Current Type Cutout Size Cutout Height Cutout Width Maximum Displayed Value Meter Accuracy Depth Minimum Temperature Maximum Temperature Approvals Measurement Range Meter Type Minimum Displayed Value Series
RS Stock No. 315-9442
Mfr. Part No.PD721MCS10V/2-001
BrandHOBUT
MYR300.30
Each
units
DC 56 (Dia.) mm - - 10V - - -25°C +40°C - - Moving Coil - -
RS Stock No. 886-1890
Mfr. Part No.EQ74-V63X2N1CAW0ST
MYR84.59
Each
units
AC 68 x 68 mm 68mm 68mm 150V - 54mm -10°C +55°C 2004 / 108 / EC (EMC Directive), 2006 / 95 / EC (Low Voltage Directive) and Amendment 93 / 68 / EEC, CE, DIN 40050, DIN 43701, DIN 43718, DIN 43802, DIN 43807, DIN 46200, DIN 46282, DIN EN 60051, DIN IEC 61554, EC 51, EC 529, IEC 1010, IS:1248, IS:9249, U 0 → 150V ac Moving Iron 0V Sigma
RS Stock No. 313-766
Mfr. Part No.D961MCS100V/2-001
BrandHOBUT
MYR260.28
Each
units
DC 92 x 92 mm - - 100V - - -25°C +40°C - - Moving Coil - -
RS Stock No. 312-892
Mfr. Part No.D96MIS150V/2-001
BrandHOBUT
MYR147.95
Each
units
AC 92 x 92 mm 92mm 92mm 150V - - -25°C +40°C - - Moving Iron - -
RS Stock No. 886-1941
Mfr. Part No.EQ94-V65X2N1CAW0ST
MYR83.71
Each
units
AC 92 x 92 mm 92mm 92mm 200V - 54mm -10°C +55°C 2004 / 108 / EC (EMC Directive), 2006 / 95 / EC (Low Voltage Directive) and Amendment 93 / 68 / EEC, CE, DIN 40050, DIN 43701, DIN 43718, DIN 43802, DIN 43807, DIN 46200, DIN 46282, DIN EN 60051, DIN IEC 61554, EC 51, EC 529, IEC 1010, IS:1248, IS:9249, U 0 → 200V ac Moving Iron 0V Sigma
RS Stock No. 196-8626
Mfr. Part No.IS 11024
MYR411.02
Each
units
DC 27 (Dia.) mm 93mm 124mm 75mV ±1.5 % 30.2mm -25°C +55°C - - Moving Coil - -
RS Stock No. 886-1850
Mfr. Part No.EQ44-V68X2N1CAW0ST
MYR83.71
Each
units
AC 45 x 45 mm 45mm 45mm 300V - 54mm -10°C +55°C 2004 / 108 / EC (EMC Directive), 2006 / 95 / EC (Low Voltage Directive) and Amendment 93 / 68 / EEC, CE, DIN 40050, DIN 43701, DIN 43718, DIN 43802, DIN 43807, DIN 46200, DIN 46282, DIN EN 60051, DIN IEC 61554, EC 51, EC 529, IEC 1010, IS:1248, IS:9249, U 0 → 300V ac Moving Iron 0V Sigma
RS Stock No. 196-8430
Mfr. Part No.IS 11006
MYR359.60
Each
units
DC 27 (Dia.) mm 59mm 76mm 75mV ±1.5 % 30.5mm -25°C +55°C - - Moving Coil - -
RS Stock No. 886-1894
Mfr. Part No.EQ74-V65X2N1CAW0ST
MYR78.24
Each
units
AC 68 x 68 mm 68mm 68mm 200V - 54mm -10°C +55°C 2004 / 108 / EC (EMC Directive), 2006 / 95 / EC (Low Voltage Directive) and Amendment 93 / 68 / EEC, CE, DIN 40050, DIN 43701, DIN 43718, DIN 43802, DIN 43807, DIN 46200, DIN 46282, DIN EN 60051, DIN IEC 61554, EC 51, EC 529, IEC 1010, IS:1248, IS:9249, U 0 → 200V ac Moving Iron 0V Sigma
RS Stock No. 886-1945
Mfr. Part No.EQ94-V67X2N1CAW0ST
MYR83.71
Each
units
AC 92 x 92 mm 92mm 92mm 250V - 54mm -10°C +55°C 2004 / 108 / EC (EMC Directive), 2006 / 95 / EC (Low Voltage Directive) and Amendment 93 / 68 / EEC, CE, DIN 40050, DIN 43701, DIN 43718, DIN 43802, DIN 43807, DIN 46200, DIN 46282, DIN EN 60051, DIN IEC 61554, EC 51, EC 529, IEC 1010, IS:1248, IS:9249, U 0 → 250V ac Moving Iron 0V Sigma
RS Stock No. 201-0324
Mfr. Part No.IS 11179
MYR292.09
Each
units
AC 26 (Dia.) mm 59mm 76mm - - - -25°C +55°C - - Moving Coil - -
RS Stock No. 313-744
Mfr. Part No.D961MCS10V/2-001
BrandHOBUT
MYR260.28
Each
units
DC 92 x 92 mm - - 10V - - -25°C +40°C - - Moving Coil - -
RS Stock No. 886-1853
Mfr. Part No.EQ44-V65X2N1CAW0ST
MYR79.06
Each
units
AC 45 x 45 mm 45mm 45mm 200V - 54mm -10°C +55°C 2004 / 108 / EC (EMC Directive), 2006 / 95 / EC (Low Voltage Directive) and Amendment 93 / 68 / EEC, CE, DIN 40050, DIN 43701, DIN 43718, DIN 43802, DIN 43807, DIN 46200, DIN 46282, DIN EN 60051, DIN IEC 61554, EC 51, EC 529, IEC 1010, IS:1248, IS:9249, U 0 → 200V ac Moving Iron 0V Sigma
RS Stock No. 202-798
Mfr. Part No.EQB72 MB:60V SCALA: 60V
MYR104.79
Each
units
AC 68 x 68 mm 68mm 68mm 60V Class 1.5 53mm - +23°C - 0 → 60V Moving Iron - -
RS Stock No. 202-489
Mfr. Part No.EQB 48 MB: 500V SCALA: 0-500V
MYR97.32
Each
units
AC 45 x 45 mm 45mm 45mm 500V Class 1.5 53mm - +23°C - 0 → 500V Moving Iron - -
RS Stock No. 886-1856
Mfr. Part No.EQ44-V67X2N1CAW0ST
MYR83.71
Each
units
AC 45 x 45 mm 45mm 45mm 250V - 54mm -10°C +55°C 2004 / 108 / EC (EMC Directive), 2006 / 95 / EC (Low Voltage Directive) and Amendment 93 / 68 / EEC, CE, DIN 40050, DIN 43701, DIN 43718, DIN 43802, DIN 43807, DIN 46200, DIN 46282, DIN EN 60051, DIN IEC 61554, EC 51, EC 529, IEC 1010, IS:1248, IS:9249, U 0 → 250V ac Moving Iron 0V Sigma
RS Stock No. 886-1957
Mfr. Part No.EQ94-V69X2N1CAW0ST
MYR83.71
Each
units
AC 92 x 92 mm 92mm 92mm 400V - 54mm -10°C +55°C 2004 / 108 / EC (EMC Directive), 2006 / 95 / EC (Low Voltage Directive) and Amendment 93 / 68 / EEC, CE, DIN 40050, DIN 43701, DIN 43718, DIN 43802, DIN 43807, DIN 46200, DIN 46282, DIN EN 60051, DIN IEC 61554, EC 51, EC 529, IEC 1010, IS:1248, IS:9249, U 0 → 400V ac Moving Iron 0V Sigma
RS Stock No. 886-1954
Mfr. Part No.EQ94-V68X2N1CAW0ST
MYR83.71
Each
units
AC 92 x 92 mm 92mm 92mm 300V - 54mm -10°C +55°C 2004 / 108 / EC (EMC Directive), 2006 / 95 / EC (Low Voltage Directive) and Amendment 93 / 68 / EEC, CE, DIN 40050, DIN 43701, DIN 43718, DIN 43802, DIN 43807, DIN 46200, DIN 46282, DIN EN 60051, DIN IEC 61554, EC 51, EC 529, IEC 1010, IS:1248, IS:9249, U 0 → 300V ac Moving Iron 0V Sigma
RS Stock No. 886-1862
Mfr. Part No.EQ44-V70X2N1CAW0ST
MYR83.71
Each
units
AC 45 x 45 mm 45mm 45mm 500V - 54mm -10°C +55°C 2004 / 108 / EC (EMC Directive), 2006 / 95 / EC (Low Voltage Directive) and Amendment 93 / 68 / EEC, CE, DIN 40050, DIN 43701, DIN 43718, DIN 43802, DIN 43807, DIN 46200, DIN 46282, DIN EN 60051, DIN IEC 61554, EC 51, EC 529, IEC 1010, IS:1248, IS:9249, U 0 → 500V ac Moving Iron 0V Sigma
RS Stock No. 312-779
Mfr. Part No.D48MIS300V/2-001
BrandHOBUT
MYR130.18
Each
units
AC 45 x 45 mm 45mm 45mm 300V - 72mm -25°C +40°C - - Moving Iron - -