Analogue Panel Voltmeters

Analogue panel voltmeters are instruments that measure the voltage, or potential deviation, between two points in an electrical circuit. A pointer moves along a scale proportional to the voltage level of the circuit. The difference in movement indicates the potential of the electrical charge between circuit points A and B. Digital panel voltmeters do the same job, but have digital readouts.

What are analogue panel voltmeters used for?

Analogue panel voltmeters can measure voltage levels in generators or fixed machinery. They're commonly used in chemical processing plants where pressure, temperature or fluid-flow readings can be converted into voltage measurements.

Types of analogue panel voltmeters

  • Moving coil voltmeters have either permanent magnets or dynamometers as measuring components with low power consumption benefits.
  • Moving iron voltmeters can measure both AC and DC currents by producing a deflective torque. The torque-to-weight ratio is high which means increased accuracy of readings.
  • Electrostatic voltmeters measure current flow based on attracting, repulsion or symmetry between two electrically charged plates. Their benefits is the high voltage range capacity of 200KV.

...
Read more Read less

Filters

Viewing 1 - 20 of 154 products
Results per page
Description Price Current Type Cutout Size Cutout Height Cutout Width Maximum Displayed Value Meter Accuracy Depth Minimum Temperature Maximum Temperature Approvals Measurement Range Meter Type Minimum Displayed Value Series
RS Stock No. 244-890
Mfr. Part No.F3PAM1801-15V
BrandHOBUT
MYR36.65
Each
units
DC 41.5 (Dia.) mm - - 15V ±8 % 15mm -20°C +40°C - - Moving Iron - -
RS Stock No. 313-659
Mfr. Part No.D721MCS30V/2-001
BrandHOBUT
MYR149.05
Each
units
DC 68 x 68 mm - - 30V - - -25°C +40°C - - Moving Coil - -
RS Stock No. 315-9458
Mfr. Part No.PD721MCS30V/2-001
BrandHOBUT
MYR216.58
Each
units
DC 56 (Dia.) mm - - 30V - - -25°C +40°C - - Moving Coil - -
RS Stock No. 313-665
Mfr. Part No.D721MCS100V/2-001
BrandHOBUT
MYR156.05
Each
units
DC 68 x 68 mm - - 100V - - -25°C +40°C - - Moving Coil - -
RS Stock No. 312-915
Mfr. Part No.D96SD500V/2-001
BrandHOBUT
MYR108.93
Each
units
AC 92 x 92 mm 92mm 92mm 500V - - -25°C +40°C - - Moving Iron - -
RS Stock No. 312-842
Mfr. Part No.D72MIS300V/2-001
BrandHOBUT
MYR155.33
Each
units
AC 68 x 68 mm 68mm 68mm 300V - - -25°C +40°C - - Moving Iron - -
RS Stock No. 886-1901
Mfr. Part No.EQ74-V69X2N1CAW0ST
MYR71.98
Each
units
AC 68 x 68 mm 68mm 68mm 400V - 54mm -10°C +55°C CE, DIN 40050, DIN 43701, DIN 43718, DIN 43802, DIN 43807, DIN 46200, DIN 46282, DIN EN 60051, DIN IEC 61554, EC 51, EC 529, IEC 1010, IS:1248, IS:9249, U, 2004 / 108 / EC (EMC Directive), 2006 / 95 / EC (Low Voltage Directive) and Amendment 93 / 68 / EEC 0 → 400V ac Moving Iron 0V Sigma
RS Stock No. 163-8820
Mfr. Part No.PM-2/30V
BrandMonacor
MYR90.00
Each
units
DC 37.5 (Dia.) mm - - 30V - 23mm - - - - Moving Coil - PM-2
RS Stock No. 313-564
Mfr. Part No.D481MCS100V/2-001
BrandHOBUT
MYR155.30
Each
units
DC 45 x 45 mm - - 100V - - -25°C +40°C - - Moving Coil - -
RS Stock No. 886-1844
Mfr. Part No.EQ44-V63X2N1CAW0ST
MYR66.27
Each
units
AC 45 x 45 mm 45mm 45mm 150V - 54mm -10°C +55°C CE, DIN 40050, DIN 43701, DIN 43718, DIN 43802, DIN 43807, DIN 46200, DIN 46282, DIN EN 60051, DIN IEC 61554, EC 51, EC 529, IEC 1010, IS:1248, IS:9249, U, 2004 / 108 / EC (EMC Directive), 2006 / 95 / EC (Low Voltage Directive) and Amendment 93 / 68 / EEC 0 → 150V ac Moving Iron 0V Sigma
RS Stock No. 392-8585
Mfr. Part No.9605000000B
MYR118.81
Each
units
DC 92 x 92 mm 92mm 92mm 500V Class 1.5 53mm - +23°C - 500V Moving Coil - -
RS Stock No. 392-8298
Mfr. Part No.9600100000B
MYR124.43
Each
units
DC 92 x 92 mm 92mm 92mm 10V Class 1.5 53mm - +23°C - 10V Moving Coil - -
RS Stock No. 196-8525
Mfr. Part No.IS 11015
MYR311.76
Each
units
DC 27 (Dia.) mm 72mm 94mm 75mV ±1.5 % 30.2mm -25°C +55°C - - Moving Coil - -
RS Stock No. 886-1960
Mfr. Part No.EQ94-V71X2N1CAW0ST
MYR67.60
Each
units
AC 92 x 92 mm 92mm 92mm 600V - 54mm -10°C 55°C CE, DIN 40050, DIN 43701, DIN 43718, DIN 43802, DIN 43807, DIN 46200, DIN 46282, DIN EN 60051, DIN IEC 61554, EC 51, EC 529, IEC 1010, IS:1248, IS:9249, U, 2004 / 108 / EC (EMC Directive), 2006 / 95 / EC (Low Voltage Directive) and Amendment 93 / 68 / EEC 0 → 600V ac Moving Iron 0V Sigma
RS Stock No. 313-750
Mfr. Part No.D961MCS30V/2-001
BrandHOBUT
MYR170.06
Each
units
DC 92 x 92 mm - - 30V - - -25°C +40°C - - Moving Coil - -
RS Stock No. 901-0548
BrandRS PRO
MYR111.61
Each
units
DC 46 x 46 mm 46mm 46mm 150V 1.5 % 39mm -25°C +50°C CE, RoHS Compliant, TUV Certified, UL E327849 0 → 150V Moving Coil 0V RS PRO
RS Stock No. 392-8642
Mfr. Part No.9600600000B
MYR118.81
Each
units
DC 92 x 92 mm 92mm 92mm 60V Class 1.5 53mm - +23°C - 60V Moving Coil - -
RS Stock No. 196-8531
Mfr. Part No.IS 11016
MYR247.15
Each
units
DC 27 (Dia.) mm 72mm 94mm 75mV ±1.5 % 30.2mm -25°C +55°C - - Moving Coil - -
RS Stock No. 901-0551
BrandRS PRO
MYR100.20
Each
units
DC 68 x 68 mm 68mm 68mm 40V ±1.5 % 36.5mm -25°C +50°C CE, RoHS Compliant, TUV Certified, UL E327849 0 → 40V Moving Coil 0V RS PRO
RS Stock No. 886-2045
Mfr. Part No.PQ94-V0TL2N1CAW0ST
MYR98.35
Each
units
DC 92 x 92 mm 92mm 92mm 15V - 54mm -10°C +55°C CE, DIN 40050, DIN 43701, DIN 43718, DIN 43802, DIN 43807, DIN 46200, DIN 46282, DIN EN 60051, DIN IEC 61554, EC 51, EC 529, IEC 1010, IS:1248, IS:9249, U, 2004 / 108 / EC (EMC Directive), 2006 / 95 / EC (Low Voltage Directive) and Amendment 93 / 68 / EEC 0 → 15V dc Moving Coil 0V Sigma
Related Products
EQN / EQB moving-iron instruments for measuring alternating ...
Description:
EQN / EQB moving-iron instruments for measuring alternating current and voltageMeasurement accuracy: Class 1.5With front zero-point regulatorOverload range of 100% with current meters for start-up bridgingProtection rating IP52Incl. pre-mounted, replaceable scaleIncl. mounting frame, terminal cover.
Polarised moving-iron meters with robust movements for use ...
Description:
Polarised moving-iron meters with robust movements for use on dc and rectified ac onlyAccuracy ±8% for battery charger applicationsOperating temperature range –20 to +40°CSnap-in panel fixingConnections 25mm, 1//4 inch spade terminals, push-on or soldered’U’ bolt fixing.
90° scale arc, accuracy class 1.5Manufactured to BS89/IEC51Frequency ...
Description:
90° scale arc, accuracy class 1.5Manufactured to BS89/IEC51Frequency range 15 to 400HzOperating temperature range: –25 to +40°CFlame retardant case to UL94V0Panel cut out: 45 x 45mm, 68 x 68mm, 92 x 92mmTerminal covers supplied separately (see accessories).
90° scale arcAccuracy class 1.5; BS89 and IEC51Flame ...
Description:
90° scale arcAccuracy class 1.5; BS89 and IEC51Flame retardant case to UL94V0Fitted with mounting bracketsOperating temperature range -25 → +40°CTerminal covers available separately48x48mm ammeters have integral scales; appropriate scales must be chosen and ordered separately for the 72x72 & 96x96mm ...