Analogue Panel Ammeters

Analogue panel ammeters measure the currents in circuits. These metered instruments measure current flow in amperes. The ampere level of the current is displayed on a dial with a red moving pointer. The current is presented in draw (how much current flows) or continuity (how uninterruptable the current is).

What are analogue panel ammeters used for?

Analogue panel ammeters determine whether erratic loads exist in electrical circuits. High ampere levels may indicate short-circuiting, unintentional grounding or indicate a defective component in the network. Low current flow points to high resistance or weak flow in the circuit.

Types of analogue panel ammeters

Analogue panel ammeters come in five types:

  • Moving coil: where magnetic deflection causes the coil to move when the current passes through the coil
  • Moving magnet: where the coil is mounted in the metered case, and a permanent magnet moves the needle
  • Moving iron: where an iron needle moves in response to an electromagnetic force from the coil.
  • Electrodynamic: where an electrodynamic magnet responds to alternating and direct current movement
  • Hot wire: where current passes through a wire that expands when heated, indicating low or high ampere levels

...
Read more Read less

Filters

Viewing 1 - 20 of 413 products
Results per page
Description Price Maximum Value Current Type Moving Element Cutout Height Cutout Width Depth Meter Accuracy Minimum Temperature Maximum Temperature Approvals Measurement Range Minimum Displayed Value Series
RS Stock No. 315-9492
Mfr. Part No.PD721MCS5A/2-001
BrandHOBUT
MYR181.92
Each
units
0/5A Direct Connected DC DC Moving Coil 72mm 72mm 30.5mm Class 1.5 -25°C +40°C - 0/5A Direct Connected DC - PD72MC
RS Stock No. 196-8468
Mfr. Part No.IS 11009
MYR311.79
Each
units
20mA DC Moving Coil 32.3mm 73.7mm 30.5mm ±1.5 % -25°C +55°C - - - -
RS Stock No. 313-520
Mfr. Part No.D481MCS75MV/4-001 0/100A
BrandHOBUT
MYR148.90
Each
units
0/100A For Shunt 75mV DC Moving Coil 48mm 48mm 43mm Class 1.5 -25°C +40°C - 0/100A For Shunt 75mV - D48MC
RS Stock No. 312-820
Mfr. Part No.D72MIS40A/1-001
BrandHOBUT
MYR97.27
Each
units
0/40A Direct Connected AC Moving Iron 72mm 72mm 38.5mm Class 1.5 -25°C +40°C - 0/40A Direct Connected - D72SD
RS Stock No. 220-756
Mfr. Part No.CV18XSZ20MAS
MYR123.70
Each
units
20mA DC Moving Coil - - 28.5mm ±2 % - - - - - -
RS Stock No. 196-8654
Mfr. Part No.IS 11026
MYR297.05
Each
units
20mA DC Moving Coil 55.5mm 121mm 30.2mm ±1.5 % -25°C 55°C - - - -
RS Stock No. 312-836
Mfr. Part No.D72MIS60A/1-001
BrandHOBUT
MYR95.10
Each
units
0/60A Direct Connected AC Moving Iron 72mm 72mm 38.5mm Class 1.5 -25°C +40°C - 0/60A Direct Connected - D72SD
RS Stock No. 315-9515
Mfr. Part No.PD721MCS50A/1-001
BrandHOBUT
MYR179.50
Each
units
0/50A Direct Connected DC DC Moving Coil 72mm 72mm 30.5mm Class 1.5 -25°C 40°C - 0/50A Direct Connected DC - PD72MC
RS Stock No. 313-485
Mfr. Part No.D481MCS75MV/4-001 0/1A
BrandHOBUT
MYR176.95
Each
units
0/1A For Shunt 75mV DC Moving Coil 48mm 48mm 43mm Class 1.5 -25°C +40°C - 0/1A For Shunt 75mV - D48MC
RS Stock No. 313-413
Mfr. Part No.D72MIS10A/1-002
BrandHOBUT
MYR121.62
Each
units
0/10A Direct Connected AC Moving Iron 72mm 72mm 38.5mm Class 1.5 -25°C +40°C - 0/10A Direct Connected - D72SD
RS Stock No. 914-5414
Mfr. Part No.D72MC75MV/0-30A
BrandHOBUT
MYR166.33
Each
units
0/30A For Shunt 75mV DC Moving Coil 72mm 72mm 38.5mm Class 1.5 -25°C +40°C BS89, CE, DIN 43700, DIN 43802, IEC 51, UL 94V0, UL 94V1 0/30A For Shunt 75mV 0A D72MC
RS Stock No. 901-0334
BrandRS PRO
MYR52.49
Each
units
60A AC Moving Iron 46mm 46mm 39mm ±1.5 % -25°C +50°C CE, RoHS Compliant, TUV Certified, UL E327849 0 → 60A 0A RS PRO
RS Stock No. 287-2116
Mfr. Part No.PD72MIS5A2/2-001 0/150/300A
BrandHOBUT
MYR132.09
Each
units
0/150/300A For 150/5A CT AC Moving Iron 72mm 72mm 30.5mm Class 1.5 -25°C +40°C - 0/150/300A For 150/5A CT - -
RS Stock No. 533-0687
Mfr. Part No.D72 DIAL 0/800A
BrandHOBUT
MYR6.66
Each
units
0/800A For 800/5A CT AC - 72mm 72mm - Class 1.5 -25°C +40°C - 0/800A For 800/5A CT - D72SD
RS Stock No. 201-880
Mfr. Part No.EQB 72 MB: WDL.5/10A SCALA: 0-100/200A
MYR102.75
Each
units
200A AC Moving Iron 72mm 72mm 53mm Class 1.5 - +23°C - - - -
RS Stock No. 315-9486
Mfr. Part No.PD721MCS1A/2-003
BrandHOBUT
MYR193.90
Each
units
0/1A Direct Connected DC DC Moving Coil 72mm 72mm 30.5mm Class 1.5 -25°C 40°C - 0/1A Direct Connected DC - PD72MC
RS Stock No. 196-8660
Mfr. Part No.IS 11027
MYR368.88
Each
units
20mA DC Moving Coil 55.5mm 121mm 30.2mm ±1.5 % -25°C +55°C - - - -
RS Stock No. 220-784
Mfr. Part No.CV20XSZ20MAS
MYR168.30
Each
units
20mA DC Moving Coil - - 28.5mm ±2 % - - - - - -
RS Stock No. 313-407
Mfr. Part No.D72SD5A/2-001 SCALED 0/5A
BrandHOBUT
MYR109.46
Each
units
0/5A Direct Connected AC Moving Iron 72mm 72mm 38.5mm Class 1.5 -25°C +40°C - 0/5A Direct Connected - D72SD
RS Stock No. 392-9128
Mfr. Part No.9651050100B
MYR103.97
Each
units
100A AC Moving Iron 92mm 92mm 53mm Class 1.5 - +23°C - - - -
Related Products
90° scale arc, accuracy class 1.5Manufactured to BS89/IEC51Frequency ...
Description:
90° scale arc, accuracy class 1.5Manufactured to BS89/IEC51Frequency range 15 to 400HzOperating temperature range –25 to +40°CFlame retardant case to UL94V0Panel cut out: 68 x 68mm, 92 x 92mmTerminal covers supplied separately (see accessories).
EQN / EQB moving-iron instruments for measuring alternating ...
Description:
EQN / EQB moving-iron instruments for measuring alternating current and voltageMeasurement accuracy: Class 1.5With front zero-point regulatorOverload range of 100% with current meters for start-up bridgingProtection rating IP52Incl. pre-mounted, replaceable scaleIncl. mounting frame, terminal cover.
Surface or flush mounted behind a panel through ...
Description:
Surface or flush mounted behind a panel through a rectangular cut-out90° deflection, pivot and jewel moving coil movementPre-printed, easy-to-fit scales (available separately)Accuracy; ±2% of Full Scale Reading (Class II)Depth 44.5mm, depth behind panel 28.5mm.
90° scale arc, accuracy class 1.5Manufactured to BS89/IEC51Frequency ...
Description:
90° scale arc, accuracy class 1.5Manufactured to BS89/IEC51Frequency range 15 to 400HzOperating temperature range: –25 to +40°CFlame retardant case to UL94V0Panel cut out: 68 x 68mm, 92 x 92mmTerminal covers supplied separately (see accessories).